Chlorine Dioxide Testing Kits
Chlorine Dioxide Testing - Chlorine
dioxide testing has traditionally been carried out by either
iodimetric titration or colourimetrically, using DPD. However, neither
test method is specific to chlorine dioxide as all other oxidising
agents react in a similar way.
Recent developments in testing and analysis technology have also
seen the introduction of a colorimetric test method based on the
bleaching effect of lisamine green under alkaline conditions. This
method is however significantly more expensive than the traditional
methods of testing. The replacement reagent costs are also increased.
SafeOx's innovative ClO2 drop test kits
Overcoming these challenges, SafeOx's innovative range of high
quality, 'easy to use' drop testers are specific to CIO2. They are
extremely cost effective and simple enough to be used by either
technical or non-technical operators.
Are the test kits easy to use?
Test results are obtained simply by multiplying the number of drops
of reagent added to the sample to achieve the required colour change,
by a predetermined factor provided in the instructions.
Note: Tests can be carried out without interference from bromine,
chlorine, chlorite, chlorate, hydrogen peroxide, peracetic acid,
or by any other oxidising species or their organic complexes.
Test kit range
SafeOx have a range of superior quality CIO2 test kits, the performance
of each kit being dependant on the required test range and specific
sample conditions encountered.
SafeOx 61313: range: 0.3 - 24 ppm
This kit is designed for the measurement of CIO2 in system water
with usage levels down to 0.3ppm, and an accuracy of 0.03ppm.
SafeOx 61314: range: 0.16 - 12 ppm
As SafeOx 61313, plus increased sensitivity to achieve an accuracy
in the region of 0.016ppm, or to achieve the accuracy of the SafeOx
61313 on a smaller sample.
SafeOx 61315: range: 0.3 - 600+ ppm
In addition to system water, SafeOx 61315 also allows testing
of CIO2 concentrations produced either by the electrolysis of
sodium chlorite, the acidification of sodium chlorite or stabilised
chlorine dioxide.
SafeOx 61316: range: 0.16 - 600+ ppm
As SafeOx 61315, plus increased lower end sensitivity, accuracy
0.016ppm.
SafeOx 61317: range: 0.3 - 600+ ppm
As SafeOx 61315, plus reagents to neutralise acidic samples produced
either by electrolysis or acidification of chlorites or stabilised
CIO2 stored at a low pH.
SafeOx 61318: range: 0.16 - 600+ ppm
As SafeOx 61317, plus increased lower end sensitivity.
Total Oxidant
An additional kit is also available for the analysis of total
oxidant levels in drinking water.
Additional Information
For more information about SafeOx products please call us on +44
(0) 161 877 2334 or e-mail info@safeox.com.